1:1 Optical Line protection Module (OLP 1:1)

OLP1:1 optical line protection system adopts the method of selective emission and selective reception. There are two fiber paths: the primary path and the secondary path.The optical power sent from Tx port will be normally transmitted through the primary path,When the primary path fails, the sender and the receiver switch to the secondary path simultaneously.Widely used in PDH, SDH system, C / DWDM system, power communication private network, CATV optical network and other optical line protection.

contact us:lina@glhcoptical.com

 

 

1.  Diagram of internal optical path of module

 

 

 

 

2 Technical Parameter

Item

Unit

Parameter

Test wavelength

nm

1310 / 1550

Insertion loss

dB

≤1.5

Return loss

dB

≥ 45

Crosstalk

dB

≥ 55

Wavelength dependent loss

dB

≤ 0.5

Polarization Dependent Loss

dB

≤ 0.2

Switching Time

ms

≤ 50

Light Detection Range

dBm

-50 +25

Photometric Resolution

dB

0.01

Photometric Accuracy

dB

≤±0.5-30 ~ +25dBm

≤±1.0-50 ~ -30dBm

Fiber Type

 

SM9/125um

Fiber Length

cm

100 ± 3

Optical Connector

 

LC/PC

Monitoring port

 

UART

Working power supply

V

4.5 ~ 5.5

Operating temperature

0 70

Storage temperature

-20 85

Module size

 

100×80×15mm

 

 

3. Diagram Dimension (Unit: mm)

 

 

 

 

 

 

 

 

 

4 Pin Definition

   

Pin Number

Pin Definition

Direction and

Type of Signal

Functional description

1

NC

 

Hanging in the air

2

NC

 

Hanging in the air

3

VCC

Power

Operating power supply, DC 5V, 1.0 A

4

NC

 

Hanging in the air

5

NC

 

Hanging in the air

6

GND

Power

GND

4

NC

 

Hanging in the air

5

NC

 

Hanging in the air

9

TXD

Output3.3V LVTTL

Serial port data sending end

10

RXD

Input3.3V LVTTL

Serial port data receiving end

11

TP 1

Input3.3V LVTTL

Module Address Bit Input (Low)

12

TP 2

Input3.3V LVTTL

Module Address Bit Input

13

TP 3

Input3.3V LVTTL

Module Address Bit Input

14

TP 4

Input3.3V LVTTL

Module Address Bit Input

15

TP 5

Input3.3V LVTTL

Module Address Bit Input (High Order)

16

ISP

Input3.3V LVTTL

Upgrade mode pin. Power-up low active.

Note: MOLEX 87833 -1620 is used for module electrical interface, and MOLEX 87568 -1694 is recommended for customer connector.

 

 

 

 